MAG-EX-LN-02P-40D
40W
120-140 lm/W
12-24VDC//100-277Vac 50-60Hz
Provides 3000K to 6500K
120°
-40 °C to +55 °C
IP66
ATEX and IECEx
| Availability: | |
|---|---|
Parameter | Specification |
|---|---|
Product model | MAG-EX-LN-02P-40D |
Product type | Explosion proof LED linear luminaire |
Rated power | 40W |
Length class | 4 foot |
Certification | ATEX and IECEx |
Hazardous area classification | Zone 1 and Zone 21 |
Ingress protection | IP66 |
Luminous efficacy | 120-140 lm/W |
Input voltage | AC100-277V, 50-60Hz or DC12-24V |
Color temperature | 3000K to 6500K |
CRI | ≥70 |
Beam angle | 120° |
Power factor | >0.95 |
THD | <10% |
Rated lifetime | 50,000 hours, L70 |
Operating temperature | -40°C to +55°C |
Surge protection | 4 kV / 6 kV surge-protection design |
Entry size | 3/4"-14 NPT, M25 × 1.5 or M26 × 1.5 |
Standard cable | 0.5 m three-core rubber cable with IEC (CE) certification |
Cable outlet arrangement | Cable outlets at both ends |
Housing | Aluminum alloy enclosure |
Cover | High-transmittance PC cover |
Product size | 1229 × 125 × 168.7 mm / 48.4 × 4.9 × 6.6 in |
Emergency function | Optional |
The MAG-EX-LN-02P-40D combines a 40W rating with the 1229 mm D-body. The 48.4-inch overall length places the fixture in the commonly specified 4-foot class. This gives buyers a clear way to compare its physical format with existing linear fixtures while keeping the exact project dimension at 1229 mm.
Cable outlets are provided at both ends. The European configuration includes two glands, allowing the cable route and connection direction to be considered with the mounting layout before installation.
The 40D has a specified efficacy range of 120-140 lm/W. Its high-efficiency LED driver is rated for a power factor above 0.95 and THD below 10%, with L70 lifetime of 50,000 hours.
A 120° beam distributes light across linear work areas, access routes and service spaces. Color temperature can be selected from 3000K to 6500K, and the standard color-rendering index is CRI ≥70.
The European 40D configuration is available with ATEX and IECEx certification for Zone 1 gas and Zone 21 dust environments. Use the full markings and certificate numbers when matching the luminaire to a project specification.
Gas marking: II 2G Ex eb mb IIC T5 Gb
Dust marking: II 2D Ex tb IIIC T75°C Db
Ingress protection: IP66
Certificate No.: SEV 21 ATEX 0578 X
Gas marking: Ex eb mb IIC T5 Gb
Dust marking: Ex tb IIIC T75°C Db
Ingress protection: IP66
Certificate No.: IECEx SEV 21.0038X
The high-strength aluminum alloy enclosure supports heat transfer and resistance to shock and vibration. The PC cover provides corrosion resistance, anti-glare performance and more than 90% light transmission.
The IP66 enclosure supports dusty and wet industrial locations, including marine environments. The operating-temperature range is -40°C to +55°C, and the electrical design includes 4 kV / 6 kV surge protection.
Select the mounting arrangement according to the supporting structure, required light direction and maintenance access.
Mount the fixture directly to the ceiling or an overhead support for a clean, low-profile installation.
The wall-mounting bracket offers an adjustable angle from 0° to ±60°, allowing the light direction to be set for the target area.
A pole-mounting arrangement is available when the luminaire needs to be positioned away from a wall or ceiling surface.
Use pendant mounting when the fixture needs to be suspended from a fixed overhead structure.
Two suspension points support chain mounting for installations that require additional hanging flexibility.
An emergency version is available for projects that require illumination during a power interruption. More than one emergency package is offered, so state the required emergency output and operating time in the quotation request.
Application areas include oil and gas refineries, drilling rigs and petrochemical facilities that require certified linear lighting for hazardous work areas and access routes.
The IP66 enclosure and corrosion-resistant PC cover support relevant areas in wastewater treatment and food and beverage facilities, subject to the site classification and project requirements.
The 1229 mm linear format can also be specified for tunnels, marine environments and indoor or outdoor industrial areas where flammable gases, vapors, combustible dust, fibers or flyings may be present.
The 40D begins the 1229 mm D-body range. Compare wattage and body length before selecting the model for a lighting layout.
Power | Model | Product Length | Page |
|---|---|---|---|
30W | MAG-EX-LN-02P-30B | 629 mm | |
50W | MAG-EX-LN-02P-50B | 629 mm | |
40W | MAG-EX-LN-02P-40D | 1229 mm | Current Model |
60W | MAG-EX-LN-02P-60D | 1229 mm | |
80W | MAG-EX-LN-02P-80D | 1229 mm | |
100W | MAG-EX-LN-02P-100D | 1229 mm |
These answers address the certification, 4-foot size class, electrical choices and ordering details most often checked for the MAG-EX-LN-02P-40D.
The MAG-EX-LN-02P-40D is a 40W explosion proof LED linear luminaire with a 1229 mm D-body. It is available with ATEX and IECEx certification for Zone 1 gas and Zone 21 dust locations.
The fixture combines an IP66 aluminum alloy enclosure, a high-transmittance PC cover, 120-140 lm/W efficacy and AC or DC input options for industrial hazardous-area projects.
Yes. The specified overall length is 1229 mm, or 48.4 inches, which places the 40D in the 4-foot fixture class. Use 1229 mm for dimensional checks because “4 foot” is the market size description rather than the exact metric length.
The 40D is rated at 40W and uses the 1229 mm D-body. The 50B is rated at 50W and uses the shorter 629 mm B-body.
Wattage and fixture length are separate selection criteria. Choose the model from the required lighting layout, available installation space and specified power rather than assuming that the longer fixture automatically has a higher wattage.
The 40D, 60D, 80D and 100D models all use the 1229 mm body in the current European quotation. The 40D is the lowest-wattage option in this group.
The series shares the same listed efficacy range, beam angle, input range and certification framework. The required rated power should be confirmed for each project.
The gas markings are II 2G Ex eb mb IIC T5 Gb for ATEX and Ex eb mb IIC T5 Gb for IECEx. The dust markings are II 2D Ex tb IIIC T75°C Db for ATEX and Ex tb IIIC T75°C Db for IECEx.
The certificate numbers are SEV 21 ATEX 0578 X and IECEx SEV 21.0038X. Compare the complete marking and temperature classification with the project specification before ordering.
Yes. The European certification covers Zone 1 gas and Zone 21 dust environments. Gas and dust hazards use different markings, so the relevant marking should be checked against the hazardous material and zoning information for the installation area.
The specified luminous efficacy is 120-140 lm/W. The fixture has a 120° beam angle, CRI ≥70 and a selectable color-temperature range from 3000K to 6500K.
The published information provides an efficacy range rather than a model-specific tested lumen value. Use approved photometric data for the ordered configuration when completing a project lighting calculation.
Select either AC100-277V at 50-60Hz or DC12-24V according to the project power supply. The driver specification includes power factor above 0.95, THD below 10% and a 4 kV / 6 kV surge-protection design.
The enclosure is rated IP66 for protection against dust and powerful water jets. The PC cover is corrosion resistant, and marine environments are included among the listed applications.
The fixture operates from -40°C to +55°C. Confirm the complete environmental and hazardous-area requirements for the installation rather than relying on the IP rating alone.
Entry options are 3/4"-14 NPT, M25 × 1.5 and M26 × 1.5. The European configuration has outlets at both ends, includes two glands and uses a standard 0.5 m three-core rubber cable with IEC (CE) certification.
Available mounting methods are ceiling, wall, pole, pendant and pendant chain. Wall mounting provides an adjustment range from 0° to ±60°.
The MAG-EX-LN-02P Series is designed as an LED replacement for traditional explosion proof fluorescent and tri-proof lamps. Its 4-foot length class makes the 40D relevant to retrofit comparisons with longer linear fixtures.
Before replacement, check mounting points, input voltage, cable-entry thread, required light distribution and the hazardous-area certification against the existing installation.
Yes. Emergency operation is optional. More than one emergency package is offered, so specify the required emergency output and operating time rather than requesting only an emergency version.
Include the quantity, applicable gas or dust classification, input voltage, color temperature, cable-entry size, mounting method and emergency requirement. For an emergency version, also provide the required output and operating time.
These details allow the ATEX/IECEx, electrical and mechanical configuration to be reviewed together before quotation.
Send us your hazardous-area requirement, input voltage, color temperature, cable entry, mounting method and emergency configuration. We will help you confirm the suitable 40W ATEX and IECEx D-body version for your project.