English
Home / Products / Explosion Proof LED Lights / 40W UL844 LED Explosion Proof Flood Light For Hazardous Location

loading

40W UL844 LED Explosion Proof Flood Light For Hazardous Location

MAG-J-40s is a compact 40W explosion proof LED flood light for classified industrial areas. Its 200 × 200 mm housing produces 4,800 lm and accepts beam options from 15° to 120°.
  • MAG-J-40s

  • 40W

  • 4800 lm

  • 110-130lm/W

  • AC100-277V, 50-60Hz

  • 5000K(Provides 2700K to 6500K)

  • 15°, 60°, 90°, 108° or 120°

  • -40 °C to +65 °C

  • IP66

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

40W Compact Explosion Proof LED Flood Light

MAG-J-40s delivers 4,800 lm from a 200 × 200 mm floodlight body. The compact format suits locations where the available mounting space is limited but the lighting plan still calls for a certified hazardous-area fixture.

Five beam choices cover focused equipment lighting as well as wider general illumination. A die-cast aluminum housing, 8 mm tempered glass and IP66 protection give the fixture the mechanical build expected for fixed industrial service.

IP66 explosion proof area light

Technical Specifications

Parameter

MAG-J-40s

Product type

Explosion proof LED flood light

Rated power

40W

Input voltage

AC100-277V, 50-60Hz

Luminous flux

4,800 lm

Luminous efficacy

110-130 lm/W

Color temperature

5000K standard; 2700K to 6500K available

CRI

≥70

Beam options

15°, 60°, 90°, 108° or 120°

Power factor

>0.95

THD

<10%

Rated lifetime

50,000 hours, L70

Operating temperature

-40°C to +65°C

Surge design

4 kV / 6 kV

Ingress protection

IP66

Housing

ADC12 die-cast aluminum

Lens

8 mm tempered glass, light transmission >90%

Mechanical performance

Shock and vibration resistant

Standard cable entry

M25 × 1.5

Optional cable entries

M26 × 1.5 or 3/4"-14 NPT

Standard cable

0.5 m three-core rubber cable with IEC (CE) certification

Fixture size

200 × 200 × 147 mm / 7.8 × 7.8 × 5.7 in

Net weight

4 kg / 8.8 lb

Dimension Drawing

Dimension Drawing

Product Highlights

  • Compact 40W format: 200 × 200 × 147 mm fixture with a 4 kg net weight.

  • Declared output: 4,800 lm with 110-130 lm/W luminous efficacy.

  • Five beam choices: 15°, 60°, 90°, 108° and 120°.

  • Wide-range input: AC100-277V, 50-60Hz with a Mean Well HLG series driver.

  • Industrial enclosure: IP66 ADC12 die-cast aluminum body and 8 mm tempered glass.

  • Temperature capability: -40°C to +65°C operating range.

  • Connection options: M25 × 1.5 standard entry; M26 × 1.5 and 3/4"-14 NPT optional.

  • Installation flexibility: ceiling, drop, wall, U-bracket and pole arrangements.

Explosion Proof LED Lighting For Hazardous Areas

Compact 200 mm Flood Light for Classified Areas

The square housing measures 200 mm across and 147 mm deep. That smaller footprint is useful on pipe racks, equipment skids, access platforms and structural members where a larger floodlight would obstruct nearby equipment or require heavier supports.

At 4 kg net weight, the fixture is easier to position on compact brackets than the higher-wattage models in the range.

Optical Output and Beam Selection

The 40W model is rated at 4,800 lm. Beam selection changes where that light is placed: 15° supports a tighter throw, 60° and 90° cover medium-width work zones, and 108° or 120° spread light across broader areas.

5000K is the standard color temperature. Project-specific orders can be specified from 2700K to 6500K, with CRI ≥70.

Industrial Housing and Thermal Design

The body is ADC12 die-cast aluminum, paired with an 8 mm tempered-glass lens. Glass transmission is specified above 90%. The enclosure is rated IP66 and the construction is described as resistant to shock and vibration.

The stated operating range is -40°C to +65°C. Confirm the permitted ambient temperature against the required certification marking and nameplate before installing the fixture in a classified location.

Electrical Supply and Cable Entry

MAG-J-40s operates from AC100-277V at 50-60Hz. The 40W configuration uses a Mean Well HLG series driver, with power factor above 0.95, THD below 10% and a 4 kV / 6 kV surge design.

M25 × 1.5 is the standard cable entry. M26 × 1.5 and 3/4"-14 NPT can be specified for projects using a different connection standard. The standard lead is a 0.5 m three-core rubber cable with IEC (CE) certification.

ATEX, IECEx and UL884 Certification

ATEX Markings

  • Gas: II 2G Ex eb mb op is IIC T4 Gb

  • Dust: II 2D Ex op is tb IIIC T95°C Db

  • Certificate: IEP 19ATEX 0714

IECEx Marking

  • Gas: Ex ec IIC T4 Gc

  • Certificate: IECEx UL 18.0046

UL884

Certification of Explosion Proof Flood Light

Mounting Options

Available mounting illustrations cover ceiling, drop, wall, U-bracket and pole installations. Select the arrangement according to the support structure, aiming requirement and cable route.

  • Ceiling mount: direct attachment below a horizontal support.

  • Drop mount: suspended position below overhead steelwork.

  • Wall mount: installation on a vertical structural face.

  • U-bracket mount: adjustable aiming for floodlighting duties.

  • Pole mount: stand-off installation on a suitable pole or support.

installation methods of hazardous area flood light
installation methods of hazardous area flood light

Typical Industrial Applications

The compact housing and selectable beam make MAG-J-40s suitable for evaluation in fixed lighting positions such as:

  • Oil and gas processing areas

  • Offshore and marine industrial facilities

  • Wastewater treatment plants

  • Petrochemical and general process installations

  • Equipment skids, platforms and access routes

Suitability depends on the site classification, full Ex marking, ambient temperature, supply voltage, corrosion conditions and installation method.

Typical Industrial Applications

MAG-J Series Power Selection

The three planned models address different output and housing-size requirements. MAG-J-40s is the compact option; MAG-J-100 and MAG-J-200 are the higher-output choices.

Model

Rated Power

Declared Luminous Flux

Fixture Size

Page Link

MAG-J-40s

40W

4,800 lm

200 × 200 × 147 mm

Current Model

MAG-J-100

100W

12,000 lm

300 × 300 × 165 mm

View 100W model

MAG-J-200

200W

24,000 lm

400 × 400 × 169 mm

View 200W model

Ordering Information

Include the following items with the enquiry so the configuration can be checked before quotation:

  • Required quantity and delivery destination

  • Site classification and complete required Ex marking

  • ATEX, IECEx or market-specific certification route

  • Beam angle: 15°, 60°, 90°, 108° or 120°

  • Color temperature from 2700K to 6500K

  • Cable-entry thread: M25 × 1.5, M26 × 1.5 or 3/4"-14 NPT

  • Ceiling, drop, wall, U-bracket or pole mounting

  • Lighting layout or target illuminance, when available

  • Required certificate copies and nameplate information

MAG-J-40s FAQs

What output does the 40W fixture provide?

The declared luminous flux is 4,800 lm, with luminous efficacy specified at 110-130 lm/W.

Which beam angle should be selected?

Use 15° for a narrow throw, 60° or 90° for medium-width equipment and work areas, and 108° or 120° for broader general lighting. Final selection should follow a lighting calculation using the approved photometric file.

Is 5000K the only color temperature?

No. 5000K is standard, while color temperatures from 2700K to 6500K are available. The CRI is at least 70.

What input voltage does MAG-J-40s use?

The listed input is AC100-277V at 50-60Hz. The driver for this 40W model is identified as Mean Well HLG series.

Which cable-entry threads are available?

M25 × 1.5 is standard. M26 × 1.5 and 3/4"-14 NPT are optional. Specify the required thread with the order so it matches the project cable gland or conduit system.

What environmental limits should be checked?

The enclosure is rated IP66 and the stated operating range is -40°C to +65°C. The installation review should also check the certification marking, permitted ambient, corrosion exposure and cable-entry sealing.

Is an emergency battery included?

No emergency package is confirmed for the standard MAG-J-40s quotation. If emergency operation is required, request a separate technical confirmation before including it in the project specification.

Request a MAG-J-40s Configuration and Quotation

Send the hazardous-area classification, quantity, beam angle, color temperature, cable-entry thread and mounting method. The required certification documents can then be checked against the proposed configuration before quotation.

Previous: 
Next: 
Get in touch
Illuminating Dreams, Lighting the Future.
Products
Applications
Links
Contact Us
   +86-15051960989
    A2 Building, Shimao Plaza, Xinbei District, Changzhou
© COPYRIGHT 2025 CHANGZHOU TOPTREE AUTO LAMP CO., LTD ALL RIGHTS RESERVED.