MAG-EX-LN-02P-50B brings a 50W rating to the compact 629 mm body. Its 120° beam and diffusing PC cover provide broad linear lighting for equipment areas, work platforms and service routes. American standard UL844. Choose AC or DC input, the mounting arrangement and an optional emergency package to suit the project.
  • MAG-EX-LN-02P-50B

  • 50W

  • 120-140lm/W

  • 12-24VDC/100-277Vac 50-60Hz

  • Provides 3000K to 6500K

  • 120°

  • -40 °C to +55 °C

  • IP66

Availability:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

50W Explosion Proof Linear LED Light

MAG-EX-LN-02P-50B brings a 50W rating to the compact 629 mm body. Its 120° beam and diffusing PC cover provide broad linear lighting for equipment areas, work platforms and service routes. American standard UL844. Choose AC or DC input, the mounting arrangement and an optional emergency package to suit the project.

MAG-EX-LN-02P-50B 50W linear light, American standard UL844, 629 mm body

Technical Parameters

Parameter

Specification

Product model

MAG-EX-LN-02P-50B

Product type

LED explosion proof linear light

Version

American standard UL844

Rated power

50W

Ingress protection

IP66

Luminous efficacy

120-140 lm/W

Input voltage

AC100-277V, 50-60Hz or DC12-24V

Color temperature

3000K to 6500K

CRI

≥70

Beam angle

120°

Power factor

>0.95

THD

<10%

Rated lifetime

50,000 hours, L70

Operating temperature

-40°C to +55°C

Power supply

High-efficiency LED driver

Surge protection

4 kV / 6 kV surge-protection design

Housing

Aluminum alloy enclosure

Cover

High-transmittance PC cover

Product size

629 × 125 × 168.7 mm

Emergency function

Optional

Dimensional Drawing

Dimensional Drawing of hazardous area lighting

A higher power option without a longer enclosure

The 50B is the 50W option in the short-body range. It shares the 629 mm length of the 30B, giving buyers a choice of power ratings within the same body-length category. It is a useful option where equipment, pipework or structural spacing limits the length of the luminaire.

The fixture combines an aluminum alloy enclosure with a diffusing PC cover. Its linear form distributes light along work areas and access routes, with ceiling, wall and suspended mounting choices for different structures.

Wide-beam lighting with selectable color temperature

A 120° beam provides broad coverage around the mounting position. The PC cover diffuses the light and reduces direct views of individual LEDs, while light transmission above 90% supports efficient delivery through the cover.

Choose a color temperature between 3000K and 6500K. CRI is ≥70 and luminous efficacy is 120–140 lm/W. For extensions to existing lighting, specify the CCT alongside the power rating to keep neighboring fixtures visually consistent.

50B optical specification: 120–140 lm/W, 120 degree beam and 3000K–6500K

Electrical options for AC and low-voltage DC circuits

AC100–277V, 50–60Hz

The AC version uses a high-efficiency LED driver, with power factor above 0.95 and total harmonic distortion below 10%. The electrical specification includes a 4 kV / 6 kV surge-protection design.

DC12–24V

A separate DC input configuration is available for low-voltage supplies. Select the input version at ordering; the AC and DC ratings do not describe a single interchangeable driver.

Enclosure and service conditions

The aluminum alloy housing conducts heat away from the light source and provides a rigid enclosure for industrial service. The construction is shock and vibration resistant, with a corrosion-resistant PC cover and IP66 protection.

Operating ambient temperature is -40°C to +55°C. Rated life is 50,000 hours at L70, and the standard warranty is five years. Keep the housing and cover accessible for inspection and cleaning when planning the installation.

50B aluminum housing and PC cover, IP66 enclosure and ambient temperature range

3/4 NPT entries at both ends

Both ends of the fixture have 3/4 NPT entry openings. The base configuration excludes cable glands, so the connection components can be specified for the actual cable or conduit arrangement.

Include the cable type, diameter and entry usage in the order. Two-end access does not establish a through-wiring rating; confirm the terminal and circuit arrangement if the project calls for interconnected fixtures.

50B bare 3/4 NPT end entry with cable glands ordered separately

Mount it to the available structure

Choose ceiling, wall, pole, pendant or pendant-chain mounting to suit the support structure. Wall mounting provides adjustment from 0° to ±60°, allowing the fixture to be aimed toward the work area. Specify the mounting kit separately from the electrical connection components.

This version has 3/4 NPT cable entry openings at both ends. Cable glands are not included. Select the connection components for the cable or conduit arrangement and provide a suitable closure for any unused entry.

1. Ceiling Mounting

Mount the fixture directly to the ceiling or an overhead support for a clean, low-profile installation.

Ceiling Mounting of Explosion Proof LED Linear Light

2. Wall Mounting

The wall-mounting bracket offers an adjustable angle from 0° to ±60°, allowing the light direction to be set for the target area.

Wall Mounting of Explosion Proof LED Linear Light

3. Pole Mounting

A pole-mounting arrangement is available when the luminaire needs to be positioned away from a wall or ceiling surface.

Pole Mounting of Explosion Proof LED Linear Light

4. Pendant Mounting

Use pendant mounting when the fixture needs to be suspended from a fixed overhead structure.

Pendant Mounting of Explosion Proof LED Linear Light

5. Pendant Chain Mounting

Two suspension points support chain mounting for installations that require additional hanging flexibility.

Pendant Chain Mounting of Explosion Proof LED Linear Light

Installation Display

Installation Display

Emergency operation is an optional configuration

Specify an emergency package when the installation requires light after loss of the normal supply. Quoted choices include 8W for 1.5 hours or 12W for 3 hours. These are emergency-mode ratings, separate from the 50W normal-operation rating.

Select the required output and runtime when requesting a quotation. Final battery configuration and operating conditions need confirmation for the chosen package.

Where to consider the 50B

The linear format can be specified for service routes and work areas in oil and gas facilities, petrochemical plants, wastewater-treatment facilities, food and beverage facilities, tunnels and marine environments. Match the ordered configuration to the location’s electrical and environmental requirements.

Access routes and service spaces

The short body fits into layouts with limited space between structural members or equipment. Ceiling and suspended arrangements keep the light above the route; check spacing and shadows against the required light level.

Equipment-side lighting

Wall and pole arrangements provide alternatives where there is no suitable overhead fixing point. Position the light so equipment does not block the beam and the cable entries remain accessible for maintenance.

applicaiton of explosion proof LED light

Available MAG-EX-LN-02P American standard UL844 Models

Power

Model

Product Length

Page Link

30W

MAG-EX-LN-02P-30B

629 mm

View 30W Model

50W

MAG-EX-LN-02P-50B

629 mm

Current Model

40W

MAG-EX-LN-02P-40D

1229 mm

View 40W Model

50W

MAG-EX-LN-02P-50D

1229 mm

View 50W Model

60W

MAG-EX-LN-02P-60D

1229 mm

View 60W Model

75W

MAG-EX-LN-02P-75D

1229 mm

View 75W Model

Frequently Asked Questions

Why choose the 50B instead of the 30B?

The MAG-EX-LN-02P-50B is rated at 50W, while the 30B is rated at 30W. Both use a 629 mm body. Consider the 50B when the lighting schedule calls for the higher power option but space still favors the short enclosure. The shared body length does not establish identical mounting kits or a specific increase in illuminance; check the selected configuration and lighting calculation.

Will the 120° beam suit a narrow walkway?

A 120° beam is a wide distribution rather than a narrow spotlight. It can illuminate the walkway and nearby equipment, but walls, pipework and mounting position can affect how much light reaches the route. Review the layout for shadows and spill light. Beam angle alone is not enough to select a mounting height or guarantee an even light level.

Can an AC unit be connected to a 24V DC supply?

No automatic AC/DC compatibility is specified. Order either the AC100–277V, 50–60Hz configuration or the DC12–24V configuration to match the circuit. State the actual voltage in the purchase order. For a DC installation, cable sizing and voltage drop should be assessed for the selected load and cable run rather than copied from an AC installation.

What should I include in a mounting request?

Identify the support surface, preferred mounting method and required light direction. Ceiling, wall, pole, pendant and pendant-chain options are available, with 0° to ±60° adjustment in the wall arrangement. Include photographs or a drawing if space is restricted. The chosen hardware must support the 4.6 kg fixture and allow access to its entry points.

Does the fixture come ready for a gland connection?

The American-standard configuration has 3/4 NPT openings at both ends, but cable glands are separate items. Supply the cable type and outside diameter when requesting the connection package. Specify how each end will be used and include suitable closure components for unused openings. Do not assume the European version’s gland or cable package is included.

Can the two entry points be used to link several lights?

Two-end access provides connection positions; it does not by itself confirm that the fixture is rated for through-wiring. Before linking fixtures, establish the terminal arrangement, conductor capacity and permitted circuit load for the ordered configuration. The total load and connection components must be considered together, rather than deriving a linking limit from the 50W rating alone.

How should emergency lighting be specified for the 50B?

Choose the required emergency output and duration separately from the normal 50W rating. Quoted options include 8W for 1.5 hours and 12W for 3 hours, subject to final battery-package confirmation. Use the selected emergency output when checking the emergency layout; normal-operation performance should not be substituted for battery-mode performance.

Is this configuration suitable for outdoor industrial areas?

The fixture has an IP66 enclosure and a specified ambient range of -40°C to +55°C. Outdoor selection should also consider the cable entry components, exposure conditions and the site’s requirements. IP66 should not be used as a substitute for a chemical-compatibility, immersion or salt-spray test rating. Include unusual exposure conditions with the inquiry.

Order the 50W configuration for your installation

Specify MAG-EX-LN-02P-50B, American standard UL844, and send the quantity, supply voltage, color temperature and mounting method through the product inquiry form. Add cable details and any emergency-output requirement so the accessories and battery option can be quoted with the fixture.

Previous: 
Next: 
Get in touch
Illuminating Dreams, Lighting the Future.
Products
Applications
Links
Contact Us
   +86-15051960989
    A2 Building, Shimao Plaza, Xinbei District, Changzhou
© COPYRIGHT 2025 CHANGZHOU TOPTREE AUTO LAMP CO., LTD ALL RIGHTS RESERVED.